\(\renewcommand{\AA}{\text{Å}}\)

read_restart command

Syntax

read_restart file
  • file = name of binary restart file to read in

Examples

read_restart save.10000
read_restart restart.*

Description

Read in a previously saved system configuration from a restart file. This allows continuation of a previous run. Details about what information is stored (and not stored) in a restart file is given below. Basically this operation will re-create the simulation box with all its atoms and their attributes as well as some related global settings, at the point in time it was written to the restart file by a previous simulation. The simulation box will be partitioned into a regular 3d grid of rectangular bricks, one per processor, based on the number of processors in the current simulation and the settings of the processors command. The partitioning can later be changed by the balance or fix balance commands.

Deprecated since version 23Jun2022.

Atom coordinates that are found to be outside the simulation box when reading the restart will be remapped back into the box and their image flags updated accordingly. This previously required specifying the remap option, but that is no longer required.

Restart files are saved in binary format to enable exact restarts, meaning that the trajectories of a restarted run will precisely match those produced by the original run had it continued on.

Some information about a restart file can be gathered directly from the command line when using LAMMPS with the -restart2info command line flag. On Unix-like operating systems (like Linux or macOS), one can also configure the “file” command line program to display basic information about a restart file

The binary restart file format was not designed with backward, forward, or cross-platform compatibility in mind, so the files are only expected to be read correctly by the same LAMMPS executable on the same platform. Changes to the architecture, compilation settings, or LAMMPS version can render a restart file unreadable or it may read the data incorrectly. If you want a more portable format, you can use the data file format as created by the write_data command. Binary restart files can also be converted into a data file from the command line by the LAMMPS executable that wrote them using the -restart2data command line flag.

Several things can prevent exact restarts due to round-off effects, in which case the trajectories in the 2 runs will slowly diverge. These include running on a different number of processors or changing certain settings such as those set by the newton or processors commands. LAMMPS will issue a warning in these cases.

Certain fixes will not restart exactly, though they should provide statistically similar results. These include fix shake and fix langevin.

Certain pair styles will not restart exactly, though they should provide statistically similar results. This is because the forces they compute depend on atom velocities, which are used at half-step values every timestep when forces are computed. When a run restarts, forces are initially evaluated with a full-step velocity, which is different than if the run had continued. These pair styles include granular pair styles, pair dpd, and pair lubricate.

If a restarted run is immediately different than the run which produced the restart file, it could be a LAMMPS bug, so consider reporting it if you think the behavior is a bug.

Because restart files are binary, they may not be portable to other machines. In this case, you can use the -restart command-line switch to convert a restart file to a data file.

Similar to how restart files are written (see the write_restart and restart commands), the restart filename can contain two wild-card characters. If a “*” appears in the filename, the directory is searched for all filenames that match the pattern where “*” is replaced with a timestep value. The file with the largest timestep value is read in. Thus, this effectively means, read the latest restart file. It’s useful if you want your script to continue a run from where it left off. See the run command and its “upto” option for how to specify the run command so it does not need to be changed either.

If a “%” character appears in the restart filename, LAMMPS expects a set of multiple files to exist. The restart and write_restart commands explain how such sets are created. Read_restart will first read a filename where “%” is replaced by “base”. This file tells LAMMPS how many processors created the set and how many files are in it. Read_restart then reads the additional files. For example, if the restart file was specified as save.% when it was written, then read_restart reads the files save.base, save.0, save.1, … save.P-1, where P is the number of processors that created the restart file.

Note that P could be the total number of processors in the previous simulation, or some subset of those processors, if the fileper or nfile options were used when the restart file was written; see the restart and write_restart commands for details. The processors in the current LAMMPS simulation share the work of reading these files; each reads a roughly equal subset of the files. The number of processors which created the set can be different the number of processors in the current LAMMPS simulation. This can be a fast mode of input on parallel machines that support parallel I/O.


Here is the list of information included in a restart file, which means these quantities do not need to be re-specified in the input script that reads the restart file, though you can redefine many of these settings after the restart file is read.

Here is a list of information not stored in a restart file, which means you must re-issue these commands in your input script, after reading the restart file.

The newton command has two settings, one for pairwise interactions, the other for bonded. Both settings are stored in the restart file. For the bond setting, the value in the file will overwrite the current value (at the time the read_restart command is issued) and warn if the two values are not the same and the current value is not the default. For the pair setting, the value in the file will not overwrite the current value (so that you can override the previous run’s value), but a warning is issued if the two values are not the same and the current value is not the default.

Note that some force field styles (pair, bond, angle, etc) do not store their coefficient info in restart files. Typically these are many-body or tabulated potentials which read their parameters from separate files. In these cases you will need to re-specify the pair_coeff, bond_coeff, etc commands in your restart input script. The doc pages for individual force field styles mention if this is the case. This is also true of pair_style hybrid (bond hybrid, angle hybrid, etc) commands; they do not store coefficient info.

As indicated in the above list, the fixes used for a simulation are not stored in the restart file. This means the new input script should specify all fixes it will use. However, note that some fixes store an internal “state” which is written to the restart file. This allows the fix to continue on with its calculations in a restarted simulation. To re-enable such a fix, the fix command in the new input script must be of the same style and use the same fix-ID as was used in the input script that wrote the restart file.

If a match is found, LAMMPS prints a message indicating that the fix is being re-enabled. If no match is found before the first run or minimization is performed by the new script, the “state” information for the saved fix is discarded. At the time the discard occurs, LAMMPS will also print a list of fixes for which the information is being discarded. See the doc pages for individual fixes for info on which ones can be restarted in this manner. Note that fixes which are created internally by other LAMMPS commands (computes, fixes, etc) will have style names which are all-capitalized, and IDs which are generated internally.

Likewise, the computes used for a simulation are not stored in the restart file. This means the new input script should specify all computes it will use. However, some computes create a fix internally to store “state” information that persists from timestep to timestep. An example is the compute msd command which uses a fix to store a reference coordinate for each atom, so that a displacement can be calculated at any later time. If the compute command in the new input script uses the same compute-ID and group-ID as was used in the input script that wrote the restart file, then it will create the same fix in the restarted run. This means the re-created fix will be re-enabled with the stored state information as described in the previous paragraph, so that the compute can continue its calculations in a consistent manner.

Note

There are a handful of commands which can be used before or between runs which may require a system initialization. Examples include the “balance”, “displace_atoms”, “delete_atoms”, “set” (some options), and “velocity” (some options) commands. This is because they can migrate atoms to new processors. Thus they will also discard unused “state” information from fixes. You will know the discard has occurred because a list of discarded fixes will be printed to the screen and log file, as explained above. This means that if you wish to retain that info in a restarted run, you must re-specify the relevant fixes and computes (which create fixes) before those commands are used.

Some pair styles, like the granular pair styles, also use a fix to store “state” information that persists from timestep to timestep. In the case of granular potentials, it is contact information between pairs of touching particles. This info will also be re-enabled in the restart script, assuming you re-use the same granular pair style.

LAMMPS allows bond interactions (angle, etc) to be turned off or deleted in various ways, which can affect how their info is stored in a restart file.

If bonds (angles, etc) have been turned off by the fix shake or delete_bonds command, their info will be written to a restart file as if they are turned on. This means they will need to be turned off again in a new run after the restart file is read.

Bonds that are broken (e.g. by a bond-breaking potential) are written to the restart file as broken bonds with a type of 0. Thus these bonds will still be broken when the restart file is read.

Bonds that have been broken by the fix bond/break command have disappeared from the system. No information about these bonds is written to the restart file.


Restrictions

none

Default

none